When I try to upgrade to a new version, the unit reverts to the old version.
There can be combinations of settings that become invalid in the
new version. Almost every new version comes with a whole set of new
error checks, which means that your valid old configuration can be an
invalid configuration with the new version.
The first step is to read through the release note to see if any
new error checkers were introduced, and to read the upgrade
instruction for the upgrade. Hopefully you find the setting there.
If you don't, or if you think this takes too much time, this is a
workaround for almost any such upgrade issue:
- Make a backup of your configuration (as a backup database or CLI
file).
- Load the Factory configuration.
- Set an IP address for the Ingate box.
- Go to the Access Control page and select a configuration address
for your Ingate box. Also add your workstation as a Configuration
Computer.
- Apply the new configuration.
- Upgrade to the new version.
- Load the backup configuration again and correct the invalid
settings.
- Apply the configuration.
« BACK
|